P/NO : MFL67870304
Please read this manual carefully before operating
your set and retain it for future reference.
This product contains Fluorinated Greenhouse Gases. (R410A)
Floor Standing Type(Console)
Original instruction
[
Representative
]
LG Electronics Inc. EU Representative : LG Electronics European Shared
Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-
gu, Changwon-si, Gyeongsangnam-do, KOREA
OWNER’S MANUAL
AIR
CONDITIONER
ITALIANO ESPAÑOL
FRANÇAIS
DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
ENGLISH
1,MFL67870304,영영 17. 7. 20. 영영 10:03 Page 1
Zobrazit stránku 0
1 2 3 4 5 6 ... 22 23

Shrnutí obsahu

Strany 1 - CONDITIONER

www.lg.comP/NO : MFL67870304Please read this manual carefully before operatingyour set and retain it for future reference.※ This product contains Fluo

Strany 2 - TABLE OF CONTENTS

10 Air ConditionerPreparation Before Operation1. Choose a suitable place where its safe & easy to reach.2. Fix the holder to wall etc with the sup

Strany 3 - Safety Precautions

Owner's Manual 11Preparation Before OperationENGLISHThe controls will look like the following.* Some functions may not be supported, depending o

Strany 4 - 4 Air Conditioner

Turning on the breaker closes the flap. (This is a normal procedure)• Be careful not to cool (heat) the room too much. Keeping the temperature setting

Strany 5 - Owner's Manual 5

Owner's Manual 13Operating InstructionsCoolingAuto Operation orAuto ChangeoverHealthyDehumidificationHeating(Heat pump model only)Air Circulatio

Strany 6 - 6 Air Conditioner

14 Air ConditionerOperating InstructionsIf you select the dehumidification mode on the OPERATION MODESELECTION button, the product starts to run the d

Strany 7 - Owner's Manual 7

Owner's Manual 15Operating InstructionsENGLISHSelect Auto Clean Operation by the function setting button( ).Now whenever the unit is turne

Strany 8 - Electrical Safety

16 Air ConditionerOperating InstructionsEnergy-saving cooling mode can save energy in cooling operation, because it can operate efficiently by setting

Strany 9 - Product Introduction

Owner's Manual 17Operating InstructionsPress the SLEEP MODE AUTO button to set the time when you want the unit to stop automatically. The timer

Strany 10 - Preparation Before Operation

18 Air ConditionerOperating InstructionsThe Upper Horizontal Vane can be adjusted by using the remote controller.1. Press the ON/OFF button to start t

Strany 11 - Wireless Remote Controller

Owner's Manual 19Operating InstructionsForced operation is used when the remote controllercan't be used. The operation will be started if t

Strany 12 - Setting the Current Time

2 Air ConditionerAir Conditioner Owner’s ManualTABLE OF CONTENTSFOR YOUR RECORDSWrite the model and serial numbers here:Model #Serial #You can find th

Strany 13 - Operating Instructions

20 Air ConditionerMaintenance and ServiceClean the unit with a soft dry cloth. Do not use bleach or abrasives.Never use any of these • Water hotter th

Strany 14 - Auto Operation

Owner's Manual 21The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the hea

Strany 15 - Air Circulation Operation

22 Air ConditionerMaintenance and ServiceThe air conditioner may be operating abnormally when:Problemn The fuse is blown/circuitbreaker is tripped.n P

Strany 16 - Energy-Saving Cooling Mode

1,MFL67870304,영영 17. 7. 20. 영영 10:03 Page 200

Strany 17 - Timer Setting

Owner's Manual 3Safety PrecautionsSafety PrecautionsTo prevent injury to the user or other people and property damage, the following instruction

Strany 18 - Upper Horizontal Vane Control

4 Air ConditionerSafety PrecautionsIndoor/outdoor wiringconnections must besecured tightly and thecable should be routedproperly so that there isno f

Strany 19 - Auto Restart Function

Owner's Manual 5Safety PrecautionsENGLISHDo not place a heater orother heating appliancesnear the power cable.• There is risk of fire andelectri

Strany 20 - Maintenance and Service

6 Air ConditionerSafety PrecautionsCAUTIONTwo or more people mustlift and transport theproduct. • Avoid personal injury. Do not install the productwhe

Strany 21 - Operation lamp

Owner's Manual 7Safety PrecautionsENGLISHDo not tilt the unit whenremoving or uninstallingit.• The condensed waterinside can spill .Do not mix a

Strany 22 - 22 Air Conditioner

8 Air ConditionerElectrical Safety• This appliance must be properly grounded.To minimize the risk of electric shock, you must always plug into a groun

Strany 23

Owner's Manual 9Product Introduction• Operation lamp : 'Blue' lights up during Cooling / Healthy Dehumidification / Air Circulation Op