LG C Series Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Napájecí adaptéry a střídače LG C Series. LG C Series User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 127
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0


     
  
 
Installation, Operation, &
Maintenance Manual
 CAUTION, SAFETY WARNING
As with all electrical products, read manual
thoroughly before operating. Only qualied, expert
personnel should perform maintenance and
installation.Contact the nearest authorized service
facility for examination, repair, or adjustment. Do
not disassemble or repair unit; death or injury to
electrical shock or re hazard may result.
Product improvement is a continual process at
Cerus Industrial. Specications and manual data
subject to change. Consult factor for additional
information.
C Series
Micro 1Ø Input Sensorless Vector Inverter
Constant Torque
Sensorless/Space Vector Control
0.5 to 3HP, 200-230VAC
1Ø input, 3Ø output
Zobrazit stránku 0
1 2 3 4 5 6 ... 126 127

Shrnutí obsahu

Strany 1 - Maintenance Manual

        �Installation, Operation, & Maintenance Manual C

Strany 2 - SAFETY INSTRUCTIONS

Chapter 1. Basic information & precautions 1.2 Product Details 1.2.1 Appearance Front Cover: Remove it when wiring and chang

Strany 3 - OPERATING PRECAUTIONS

Chapter 11. Monitoring 11. Monitoring 11.1 Operating status monitoring z Output current Group LED Display Description Set value Min/Max range Fact

Strany 4 -

Chapter 11. Monitoring z User display select Group LED Display Parameter Name Set value Min/Max range Factory default Unit Drive group vOL [User

Strany 5 - Important User Information

Chapter 11. Monitoring 11.2 Monitoring the I/O terminal z Input terminal status monitoring Group LED Display Parameter Name Set value Min/Max rang

Strany 6 - Table of Contents

Chapter 11. Monitoring 11.3 Monitoring fault condition z Monitoring fault display Group LED Display Parameter Name Set value Min/Max range Factory

Strany 7 - 9. Basic Functions 60

Chapter 11. Monitoring Fault typeOperating status when a fault occurs11.4 Analog Output Group LED Display Parameter Name Set value Min/

Strany 8 - 14. Specifications 122

Chapter 11. Monitoring 11.5 Multi-function output terminal (MO) and Relay (30AC) Group LED display Parameter Name Setting Factory default 0 FDT-1

Strany 9 - 1.1 Important precautions

Chapter 11. Monitoring  I56: When 17 {Fault display} is selected in I54 and I55, Multi-function output terminal and relay will be activated with t

Strany 10 - 1.2 Product Details

Chapter 11. Monitoring 2: FDT-3  It activates when run frequency meets the following condition.  Active condition: Absolute value (FDT level -

Strany 11

Chapter 11. Monitoring Decel time: Run Frequency > (FDT Level – FDT Bandwidth/2) Group LED Display Parameter Name Set value Min/Max range Factory

Strany 12

Chapter 11. Monitoring 12: During run  Become active when run command is given and the inverter generates output voltage. Freq.MORun comma

Strany 13

Chapter 1. Basic information & precautions 1.3 Removal and reinstallation 1.3.1 Removal of the front cover z To change parameter setting: Pre

Strany 14 - Chapter 2. Installation

Chapter 12. Protective functions 12.1 Electronic Thermal Group LED display Parameter Name Set value Min/Max setting Factory default Unit F50 [Elec

Strany 15 - 2.2 Dimensions

Chapter 12. Protective functions 12.2 Overload Warning and trip z Overload warning Group LED Display Parameter Name Set value Min/Max setting Fact

Strany 16 - 1.5, 2.2 kW (2~3HP)

Chapter 12. Protective functions 12.3 Stall prevention Group LED Display Parameter Name Set value Min/Max setting Factory default Unit F59 [Stall p

Strany 17 - 3.1 Terminal wiring

Chapter 12. Protective functions CurrentFreq.During accelerationDuring constant runF60t1 t2Multi-function o

Strany 18

Chapter 12. Protective functions 12.5 External trip signal Group LED display Description Set Value Min/Max setting Factory default Unit I20 [Multi-f

Strany 19

Chapter 12. Protective functions 12.6 Inverter Overload  Inverter overload prevention function is activated when the current above inverter rate

Strany 20

Chapter 12. Protective functions  I62: When no frequency command is given for the time set in I63, set the drive mode as the table below. 0 Conti

Strany 21

Chapter 13. Troubleshooting & Maintenance 13. Troubleshooting & Maintenance 13.1 Protective functions When a fault occurs, the cause m

Strany 22

Chapter 13. Troubleshooting & Maintenance Used for the emergency stop of the inverter. The inverter instantly turns off the output when the EST t

Strany 23 - - Basic configuration

Chapter 13. Troubleshooting & Maintenance 13.2 Fault Remedy Protective functions Cause Remedy  CAUTION: When an overcurrent fault occurs, oper

Strany 24

Chapter 1. Basic information & precautions z Removal for wiring input power and terminals: After removing the front cover, lift the bottom cov

Strany 25 - 5.1 Keypad features

Chapter 13. Troubleshooting & Maintenance Protective functions Cause Remedy External fault A contact input External fault B contact input z Th

Strany 26

Chapter 13. Troubleshooting & Maintenance 13.3 Precautions for maintenance and inspection CAUTION z Make sure to remove the input power while

Strany 27 - 5.3 Moving to other groups

Chapter 14. Specifications 14. Specifications 14.1 Technical data z Input & output ratings Model: CI – xxx – C2 – 1P 001 002 003 004 [HP]

Strany 28 - code of each group

14. Specifications command, H/W fault Alarm Conditions Stall prevention, Overload Momentary power loss Less than 15 msec: Continuous operation More

Strany 29 - code in Drive group “0.0”

DECLARATION OF CONFORMITY Council Directive(s) to which conformity is declared: CD 73/23/EEC and CD 89/336/EEC Units are

Strany 30

TECHNICAL STANDARDS APPLIED The standards applied in order to comply with the essential requirements of the Directives 73/23/EEC "Electrical mat

Strany 31 - Drive group

EMC INSTALLATION GUIDE Cerus inverters are tested to meet Electromagnetic Compatibility (EMC) Directive 89/336/EEC and Low Voltage (LV) Directive 73

Strany 32

Product improvement is a continual process; pricing and speci cations subject to change without notice. Cerus, Orion, Titan and associated logos are

Strany 33 - -. The set value is 0

Chapter 2. Installation 2.1 Installation precautions CAUTION z Handle the inverter with care to prevent damage to the plastic components. Do not ho

Strany 34

Chapter 2. Installation z When two or more inverters are installed or a ventilation fan is mounted in inverter panel, the inverters and ventilation

Strany 35

Chapter 2. Installation 2.2 Dimensions z 0.4, 0.75 kW (1/2~1 HP) H D W mm (inch) Dimension CI-000-C2-1

Strany 36

Chapter 2. Installation z 1.5, 2.2 kW (2~3HP) H D W mm (inch) Dimension CI-000-C2-1P CI-001-C2-1P CI-002-C2

Strany 37 - -. Return to H0

Chapter 3. Wiring 3. Wiring 3.1 Terminal wiring P4 P5 VR V1 CM I AM MO EXTG P24 P1 P2 CM P3 30A 30B 30C Termi-n

Strany 38

Chapter 3. Wiring 3.2 Specifications for power terminal block wiring CI-000-C2-1P CI-001-C2-1P CI-002-C2-1P CI-003-C2-1P Input wire size 2

Strany 39 - CHAPTER 6 - Basic operation

Chapter 3. Wiring WARNING z Use the Type 3 grounding method (Ground impedance: Below 100ohm). z Use the dedicated ground terminal to ground the in

Strany 40 - Wiring Operating pattern

SAFETY INSTRUCTIONS  Always follow safety instructions to prevent accidents and potential hazards from occurring.  In this manual, safety m

Strany 41 - STOP/RST key

Chapter 3. Wiring 3.3 I/O terminal block specification Terminal Terminal Description Wire size Torque (Nm) Note P1/P2/P3 P4/P5 Mul

Strany 42 - Chapter 6. Basic operation

Chapter 3. Wiring 3.4 PNP/NPN selection and connector for communication option CMFX24X24ICMCMResistorResistorResistor

Strany 43 - CHAPTER 7 - Function list

Chapter 3. Wiring Notes: 22

Strany 44

Chapter 4 - Basic configuration 4.1 Connection of peripheral devices to the inverter The following devices are required to operate the inverter. Pro

Strany 45

Chapter 4 - Basic configuration 4.2 Recommended MCCB, Earth leakage circuit breaker (ELB) and Magnetic contactor specification Model MCCB/ ELB(LG

Strany 46

Chapter 5. Programming keypad 5. Programming Keypad 5.1 Keypad features Buttons z RUN z STOP/RST z 4-WAY BUTTON z Potentiometer

Strany 47

Chapter 5. Programming keypad 5.2 Alpha-numeric view on the LED keypad 0 A K U 1 B L V 2 C M W 3 D N X 4 E O Y 5 F P Z 6

Strany 48

Chapter 5. Programming keypad 5.3 Moving to other groups z There are 4 different parameter groups as shown below. Drive group Function

Strany 49

Chapter 5. Programming keypad z How to move to other groups at the 1st code of each group. 1 -. The 1st code in Drive group “0.0” will be displayed

Strany 50

Chapter 5. Programming keypad 5.4 How to change the codes in a group z Code change in Drive group 1 -. In the 1st code in Drive group “0.0”, press

Strany 51

CAUTION  Do not install the drive on a flammable surface. Do not place flammable material nearby the drive. Otherwise, fire could occur.  R

Strany 52

Chapter 5. Programming keypad z For changing code from any codes other than F 0 When moving from F 1 to F 15 in Function group 1. 1 -. In F 1,

Strany 53

Chapter 5. Programming keypad 5.5 Parameter setting method z Changing parameter value in Drive group When changing ACC time from 5.0 sec to 16.

Strany 54

Chapter 5. Programming keypad When changing run frequency to 30.05 Hz in Drive group Drive group 1 -. In “0.0”, press the Prog/Ent (z) key once.

Strany 55

Chapter 5. Programming keypad z Changing parameter values in Function 1, 2 and I/O group When changing the parameter value of F 27 from 2 to 5 Func

Strany 56

Chapter 5. Programming keypad 5.6 Monitoring of operation status Monitoring output current in Drive group Drive group 1 -. In [0.0], continu

Strany 57

Chapter 5. Programming keypad How to monitor Motor rpm in Drive group when the motor is rotating in 1730 rpm. Drive group 1 -. Present run freque

Strany 58

Chapter 5. Programming keypad How to monitor fault condition in Drive group Drive groupSTOP/RSTFrequencyCurrentDuringAccelOver-currenttrip1 -. Thi

Strany 59

Chapter 5. Programming keypad z Parameter initialize How to initialize parameters of all four groups in H93 Functiongroup 2 1 -. In H0, press th

Strany 60 - 9.1 Frequency mode

Chapter 5. Programming keypad Note:38

Strany 61 - V0 input

Chapter 6. Basic operation CHAPTER 6 - Basic operation 6.1 Frequency Setting and Basic Operation Caution : The following instructions are given b

Strany 62

(2) Wiring  Do not connect a power factor correction capacitor, surge suppressor, or RFI filter to the output of the inverter.  The connection or

Strany 63

Chapter 6. Basic operation Frequency Setting via potentiometer & operating via terminals 1 -. Apply AC input power to the inverter. 2 -. Whe

Strany 64 - Freq. setting

Chapter 6. Basic operation Frequency setting via potentiometer & operating via the Run key 1 -. Apply AC input power to the inverter. 2 -.

Strany 65

Chapter 6. Basic operation Notes:42

Strany 66 - FX : Counter clockwise

Chapter 7. Function list CHAPTER 7 - Function list Drive GroupLED display Parameter name Min/Max range Description Factory defaults Adjustable duri

Strany 67

Chapter 7. Function list Function group 1LED display Parameter name Min/Max range Description Factory defaults Adjustable during run Page F 0 [Jump

Strany 68 - When H20 is 0 When H20 is 1

Chapter 7. Function list Function group 1LED display Parameter name Min/Max range Description Factory defaults Adjustable during run Page F24 [Freque

Strany 69 - When H21 is 0 When H21 is 1

Chapter 7. Function list Function group 1LED display Parameter name Min/Max range Description Factory defaults Adjustable during run Page F52 [Electr

Strany 70

Chapter 7. Function list Function group 2LED display Parameter name Min/Max range Description Factory defaults Adjustable during run PageH 0 [Jump

Strany 71

Chapter 7. Function list 1) Set H10 to 1 to be displayed. # H17, 18 is used when F2, F3 is set to 1 S-Curve. Function group 2LED display Paramet

Strany 72

Chapter 7. Function list Function group 2LED display Parameter Name Min/Max Range Description Factory defaults Adjustable during run Page H31 [Number

Strany 73 - Accel time Decel time

Important User Information The purpose of this manual is to provide the user with the necessary information to install, program, start up and to main

Strany 74

Chapter 7. Function list Function group 2LED display Parameter Name Min/Max Range Description Factory defaults Adjustable during run Page H51 [P g

Strany 75 - Base freq

Chapter 7. Function list Function group 2LED display Parameter Name Min/Max Range Description Factory defaults Adjustable during run Page H82 [2nd mo

Strany 76 - Freq, Voltage

Chapter 7. Function list I/O groupLED display Parameter name Min/Max range Description Factory defaults Adjustable during run PageI 0 [Jump code]

Strany 77

Chapter 7. Function list I/O groupLED display Parameter name Min/Max range Description Factory defaults Adjustable during run Page8 Multi Accel/Dece

Strany 78

Chapter 7. Function list I/O groupLED display Parameter name Min/Max range Description Factory defaults Adjustable during run PageI42 [Multi-Accel ti

Strany 79 - 10.1 DC brake

Chapter 7. Function list I/O groupLED display Parameter name Min/Max range Description Factory defaults Adjustable during run Page6 3 3 - 7 3 3 3

Strany 80

Chapter 7. Function list Notes: 56

Strany 81 - 10.2 Jog operation

Chapter 8. Control block diagram CHAPTER 8 - Control block diagram Frequency settingDrive modeAccel/DecelV/FcontrolPWM

Strany 82 - 10.3 Up-Down operation

Chapter 8. Control block diagram 8.1 Frequency and Drive mode setting I/O groupSt1St2St3I/O groupI30I31I32I33Step 0I/O groupI20 ~ I24Step 0-7Ste

Strany 83 - 10.4 3-Wire Operation

Chapter 8. Control block diagram 8.2 Accel/Decel setting and V/F control Reference freq. forAccel/DecelAccel/DeceltimeP1P2P3P4P5Digital input filter

Strany 84

Table of Contents Table of Contents i Safety Instructions 5 1. Basic information and precautions 9 1.1 Important precautions 9 1.2

Strany 85

Chapter 9. Basic functions CHAPTER 9 - Basic Functions 9.1 Frequency mode z Digital Frequency setting via Keypad 1 Group LED Display Paramete

Strany 86

Chapter 9. Basic functions z Analog Frequency setting via Potentiometer (V0) on the Keypad Used to prevent fluctuations in analog input signals caus

Strany 87 - 10.7 PID Control

Chapter 9. Basic functions z Analog Frequency setting via Voltage analog input (0-10V) or potentiometer on the VR terminal Group LED Display Param

Strany 88 - I 1, 6, 11

Chapter 9. Basic functions z Frequency setting via Potentiometer on the keypad + Current Analog input (0-20mA) Group LED Display Parameter Name Se

Strany 89 - 10.8 Auto tuning

Chapter 9. Basic functions z Analog Hold Group LED Display Parameter Name Set Value Min/Max Range Factory Defaults Unit Drive group Frq [Frequenc

Strany 90

Chapter 9. Basic functions 9.2 Multi-Step frequency setting Group LED Display Parameter Name Set Value Min/Max Range Factory Defaults Unit 0.0 [F

Strany 91

Chapter 9. Basic functions 9.3 Run Command setting z Run via the Run and STOP/RST key Group LED Display Parameter Name Set Value Min/Max Range F

Strany 92 - 10.11 Speed Search

Chapter 9. Basic functions z Run command setting 2 at FX and RX terminals Group LED Display Parameter Name Set Value Min/Max Range Factory Default

Strany 93

Chapter 9. Basic functions z Power On Start select Group LED Display Parameter Name Set Value Min/Max Range Factory Defaults Unit Drive group drv

Strany 94 - 10.12 Auto restart try

Chapter 9. Basic functions z Restart after fault reset Group LED display Parameter name Set value Min/Max range Factory defaults Unit Drive group

Strany 95

Table of Contents 6. Basic operation 39 6.1 Frequency Setting and Basic Operation 39 7. Function list 43 7.1 Drive Group 43

Strany 96

Chapter 9. Basic functions 9.4 Accel/Decel time and unit setting z Accel/Decel time setting based on Max frequency Group LED Display Parameter

Strany 97

Chapter 9. Basic functions z Accel/Decel time based on Run frequency Group LED display Parameter name Set value Min/Max range Factory defaults Uni

Strany 98

Chapter 9. Basic functions z Multi-Accel/Decel time setting via Multi-function terminals Group LED Display Parameter Name Set Value Min/Max Range

Strany 99

Chapter 9. Basic functions z Accel/Decel pattern setting Group LED display Parameter name Min/Max range Set value Unit F 2 [Accel pattern] 0 L

Strany 100

Chapter 9. Basic functions z Note that setting Frequency Ref. for Accel/decel (H70) is set to Max Freq and target freq is set below Max freq. the

Strany 101 - Chapter 11. Monitoring

Chapter 9. Basic functions 9.5 V/F control z Linear V/F operation Group LED Display Parameter Name Set Value Min/Max Range Factory Defaults Unit

Strany 102

Chapter 9. Basic functions 9.6 Stop mode select z Decel to stop Group LED Display Parameter Name Set Value Min/Max Range Factory Defaults Unit

Strany 103

Chapter 9. Basic functions 9.7 Frequency limit setting z Frequency limit setting based on Max and start frequency Group LED display Parameter

Strany 104 - 0 ~ 10Vdc

Chapter 9. Basic functions z Skip frequency Group LED display Parameter name Set value Min/Max range Factory defaults Unit H10 [Skip frequency s

Strany 105

Chapter 10. Advanced functions 10. Advanced functions 10.1 DC brake z Stop mode via DC brake Group LED Display Parameter Name Set value Min/Ma

Strany 106

Table of Contents 11. Monitoring 100 11.1 Operating status monitoring 100 11.2 Monitoring the I/O terminal 102 11.3 Monitoring fault c

Strany 107

Chapter 10. Advanced functions z Starting DC brake Group LED Display Parameter Name Set value Min/Max Range Factory Defaults Unit F12 [DC Brake

Strany 108

Chapter 10. Advanced functions 10.2 Jog operation Group LED display Parameter name Set value Min/Max range Factory defaults Unit Function group 1

Strany 109

Chapter 10. Advanced functions 10.3 Up-Down operation Group LED display Parameter name Set value Min/Max range Factory defaults Unit I20 [Multi-f

Strany 110 - 12.1 Electronic Thermal

Chapter 10. Advanced functions 10.4 3-Wire Operation Group LED display Parameter name Set value Min/Max range Factory defaults Unit I20 [Multi-fu

Strany 111

Chapter 10. Advanced functions 10.5 Dwell operation Group LED Display Parameter Name Set value Min/Max Range Factory Defaults Unit H 7 [Dwell fr

Strany 112 - 12.3 Stall prevention

Chapter 10. Advanced functions 10.6 Slip compensation Group LED Display Parameter Name Set value Min/Max Range Factory Defaults Unit H30 [Motor

Strany 113

Chapter 10. Advanced functions Example Rated frequency= 60Hz Rated motor RPM= 1740rpm Motor pole number= 4 Hzfs21204174060 =⎟⎠⎞⎜⎝⎛×−= H32- [Rate

Strany 114 - P5(B contact)

Chapter 10. Advanced functions 10.7 PID Control Group LED Display Parameter Name Set value Min/Max Range Factory Defaults Unit H40 [Control mod

Strany 115 - 12.7 Frequency command loss

Chapter 10. Advanced functions PID control block diagram Controlmode selectFunc. group2H40Keypad setting 2V0:PotentiometerV1 : 0

Strany 116

10. Advanced functions 10.8 Auto tuning Group LED Display Parameter Name Set value Min/Max Range Factory Defaults Unit H41 [Auto tuning] 1 0/1

Strany 117 - WARNING

Chapter 1. Basic information & precautions 1. Basic information and precautions 1.1 Important precautions Unpacking and inspection Inspect t

Strany 118 - CAUTION:

10. Advanced functions 10.9 Sensorless vector control Group LED Display Parameter Name Set value Min/Max Range Factory Defaults Unit H40 [Contr

Strany 119 - 13.2 Fault Remedy

10. Advanced functions  Factory default of motor parameters (Function group 2) H30-Motor rating [kW] H32-Rated slip freq [Hz] H33-Current rating [A

Strany 120

10. Advanced functions 10.11 Speed Search Group LED Display Parameter Name Set value Min/Max Range Factory Defaults Unit H22 [Speed Search Selec

Strany 121 - CAUTION

10. Advanced functions  H23: It limits the current during Speed search. Set as the percent of H33 – [Motor rated current].  H24, H25: Speed sea

Strany 122 - 14.1 Technical data

10. Advanced functions 10.12 Auto restart try Group LED Display Parameter Name Set value Min/Max Range Factory Defaults Unit H26 [Number of Auto R

Strany 123

10. Advanced functions 10.13 Carrier frequency select Group LED Display Parameter Name Set value Min/Max Range Factory Defaults Unit Function grou

Strany 124 - DECLARATION OF CONFORMITY

10. Advanced functions  2nd motor operation does not run 2 motors at the same time. As the figure below, when using two motors with an inverter by

Strany 125 - TECHNICAL STANDARDS APPLIED

10. Advanced functions z Password Register Group LED Display Parameter Name Set value Min/Max Range Factory Defaults Unit Function group 2 H94 [Pa

Strany 126 - EMC INSTALLATION GUIDE

10. Advanced functions z Parameter Lock Group LED Display Parameter Name Set value Min/Max Range Factory Defaults Unit H95 [Parameter lock] - 0/FFF 0

Strany 127 - Get all the latest in

10. Advanced functions Notes: 99

Komentáře k této Příručce

Žádné komentáře