INSTALLATION MANUAL
AIR
CONDITIONER
www.lg.com
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.
[
Representative
]
LG Electronics Inc. EU Representative : LG Electronics European Shared Service Center B.V.
Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[
Manufacturer
]
LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu, Changwon-si,
Gyeongsangnam-do, KOREA
4-WAY CEILING CASSETTE
Original instruction
ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
1,MFL67855506,영영,10영영(영영영) 2017. 6. 27. 영영 6:13 Page 1
Zobrazit stránku 0
1 2 3 4 5 6 ... 28 29

Shrnutí obsahu

Strany 1 - CONDITIONER

P/NO : MFL67855506INSTALLATION MANUALAIRCONDITIONERwww.lg.comPlease read this installation manual completely before installing the product.Installatio

Strany 2 - TIPS FOR SAVING ENERGY

10ENGLISHTHE INDOOR UNIT INSTALLATIONSet screw ofpaper model (4 pieces)Paper modelfor installationCeilingboard150mmCeiling boardCeiling Flat washer fo

Strany 3 - IMPORTANT SAFETY INSTRUCTIONS

ENGLISH11THE INDOOR UNIT INSTALLATION700 or less1 -1.5mClamp metal(attached) Drain hose(attached)Drain raising pipe300mm or less300mm or less300mm or

Strany 4

12ENGLISHTHE INDOOR UNIT INSTALLATIONPrecautions when laying powerwiringUse round pressure terminals for connectionsto the power terminal block.When n

Strany 5

ENGLISH13REMOTE CONTROLLER INSTALLATIONPlease fix tightly using provided screw after placing remote controller setupboard on the place where you like t

Strany 6

14ENGLISHREMOTE CONTROLLER INSTALLATIONPlease fix remote controller upper partinto the setup board attached to the sur-face of the wall, as the picture

Strany 7 - TABLE OF CONTENTS

ENGLISH15REMOTE CONTROLLER INSTALLATIONWired remote controller installationSince the room temperature sensor is in the remote controller, the remote c

Strany 8 - INSTALLATION PLACES

16ENGLISHINSTALLATION OF DECORATIVE PANEL(ACCESSORY)INSTALLATION OF DECORATIVE PANEL(ACCESSORY)The decorative panel has its installationdirection.Befo

Strany 9 - THE INDOOR UNIT INSTALLATION

ENGLISH17INSTALLATION OF DECORATIVE PANEL(ACCESSORY)6 Open two screws of control panel cover.Screw7 Connect one display connector and twovane control

Strany 10 - Indoor Unit Drain Piping

18ENGLISHTEST RUNNINGTEST RUNNINGPRECAUTIONS IN TEST RUN- The initial power supply must provide at least90% of the rated voltage.Otherwise, the air co

Strany 11 - Wiring Connection

OPTIONAL OPERATIONENGLISH19Installer Setting -Test Run ModeAfter installing the product, you must run a Test Run mode. For details related to this ope

Strany 12 - Precautions when laying power

• Do not cool excessively indoors. This may be harmful for your health and may consume moreelectricity.• Block sunlight with blinds or curtains whil

Strany 13 - <Wire guide grooves>

20OPTIONAL OPERATIONENGLISHInstaller Setting - Setting Address of Central ControlIt's the function to use for connecting central control.Please r

Strany 14 - Unit side

OPTIONAL OPERATIONENGLISH21Installer Setting -ThermistorFunction Code Thermistor settingSet Thermistor value by pressing button. (01: Remote Controlle

Strany 15 - Sun ray contact area

22OPTIONAL OPERATIONENGLISHInstaller Setting -Ceiling Height SelectionThis function is to adjust FAN Airflow rate according to ceilingheight (only cas

Strany 16 - 5 Fit the corner covers

OPTIONAL OPERATIONENGLISH23Installer Setting-Group SettingIt is a function for settings in group control, or 2-remote controller control.Function Code

Strany 17 - CN-DISPLAY

24OPTIONAL OPERATIONENGLISHFunction Code Dry Contactsetting valueSelect Dry contact setting by pressing button. (00 : Automatic, 01 : manual)3Press

Strany 18 - Thermometer

OPTIONAL OPERATIONENGLISH25Installer Setting-Celsius / Fahrenheit SwitchingThis function is used for switching the display between Celsius and Fahrenh

Strany 19 - Function Code Set

26OPTIONAL OPERATIONENGLISHInstaller Setting -Optional Function SettingSetting feature for indoor unit when air cleaning / heater / humidifier / Up/do

Strany 20 - Indoor No

HOW TO SET E.S.P?ENGLISH27HOW TO SET E.S.P?This is the function that decides the strength of the wind for each wind level and because thisfunction is

Strany 21 - Installer Setting -Thermistor

28HOW TO SET E.S.P?ENGLISH- Please be careful not to change the ESP value for each fan step.- It does not work to setup ESP value for very low/power s

Strany 22

1,MFL67855506,영영,10영영(영영영) 2017. 6. 27. 영영 6:13 Page 100

Strany 23

3IMPORTANT SAFETY INSTRUCTIONSREAD ALL INSTRUCTIONS BEFORE USING THE APPLI-ANCE.Always comply with the following precautions to avoid danger-ous situa

Strany 24

• For installation of the product, always contact the service cen-ter or a professional installation agency. - Otherwise, it may cause a fire, electri

Strany 25

IMPORTANT SAFETY INSTRUCTIONSENGLISH5- Otherwise, it may cause a fire or electrical shock.• Unplug the unit if strange sounds, smell, or smoke comesfr

Strany 26

6IMPORTANT SAFETY INSTRUCTIONSENGLISHCAUTIONInstallation• Install the drain hose to ensure that drain can be securelydone. - Otherwise, it may cause w

Strany 27 - HOW TO SET E.S.P?

ENGLISH78 INSTALLATION PLACES9 THE INDOOR UNITINSTALLATION10 Indoor Unit Drain Piping11 Wiring Connection13 REMOTE CONTROLLERINSTALLATION15 Wired remo

Strany 28

8ENGLISHINSTALLATION PLACESINSTALLATION PLACES- There should not be any heat source or steam near the unit. - There should not be any obstacles to pre

Strany 29

ENGLISH9THE INDOOR UNIT INSTALLATIONLevel gaugeCeilingCeiling boardUnit:mmUnit:mm875(Ceiling opening)787(Hanging bolt)684(Hanging bolt)671875(Ceiling