P/NO : MFL67855536INSTALLATION MANUALAIRCONDITIONERwww.lg.comPlease read this installation manual completely before installing the product.Installatio
10ENGLISHINSTALLATION PLACESINSTALLATION PLACES- There should not be any heat source or steam near the unit. - There should not be any obstacles to pr
ENGLISH11INSTALLATION PLACES- The appliance shall be installed, operated and stored in a room with a floor area larger than the mini-mum area.- Use th
12ENGLISHTHE INDOOR UNIT INSTALLATIONLevel gaugeCeilingCeiling boardUnit:mmUnit:mm875(Ceiling opening)787(Hanging bolt)684(Hanging bolt)671875(Ceiling
ENGLISH13THE INDOOR UNIT INSTALLATIONSet screw ofpaper model (4 pieces)Paper modelfor installationCeilingboard150mmCeiling boardCeiling Flat washer fo
14ENGLISHTHE INDOOR UNIT INSTALLATION700 or less1 -1.5mClamp metal(attached) Drain hose(attached)Drain raising pipe300mm or less300mm or less300mm or
ENGLISH15THE INDOOR UNIT INSTALLATIONPrecautions when laying powerwiringUse round pressure terminals for connectionsto the power terminal block.When n
16THE INDOOR UNIT INSTALLATIONENGLISHFlaring WorkMain cause for gas leakage is due to defect offlaring work. Carry out correct flaring work inthe foll
THE INDOOR UNIT INSTALLATIONENGLISH171 Compare the flared work with the figureby.2 If a flared section is defective, cut it offand do flaring work aga
18THE INDOOR UNIT INSTALLATIONENGLISH2 Set the tubing cutting line upward. Wrap the area which accommodates therear piping housing section with vinyl
REMOTE CONTROLLER INSTALLATIONENGLISH19Please fix tightly using provided screw after placing remote controller setupboard on the place where you like t
ENGLISHMODEL DESIGNATION2MODEL DESIGNATION- Product Name : Air conditioner- Model Name :- Additional Information : serial number isrefer to the barcod
20ENGLISHREMOTE CONTROLLER INSTALLATIONPlease fix remote controller upper partinto the setup board attached to the sur-face of the wall, as the picture
ENGLISH21REMOTE CONTROLLER INSTALLATIONWired remote controller installationSince the room temperature sensor is in the remote controller, the remote c
22ENGLISHINSTALLATION OF DECORATIVE PANEL(ACCESSORY)INSTALLATION OF DECORATIVE PANEL(ACCESSORY)The decorative panel has its installationdirection.Befo
ENGLISH23INSTALLATION OF DECORATIVE PANEL(ACCESSORY)5 Fit the corner covers.ScrewInstalling the grill link on the panel bodyInserting the edge into th
24ENGLISHAir conditionerunitDecorative panelFit the insulator (this part) and be careful for cool air leakageGood exampleCeilingboardCeilingboardDecor
OPTIONAL OPERATIONENGLISH25Installer Setting -Test Run ModeAfter installing the product, you must run a Test Run mode. For details related to this ope
26OPTIONAL OPERATIONENGLISHInstaller Setting - Setting Address of Central ControlIt's the function to use for connecting central control.Please r
OPTIONAL OPERATIONENGLISH27Installer Setting -ThermistorFunction Code Thermistor settingSet Thermistor value by pressing button. (01: Remote Controlle
28OPTIONAL OPERATIONENGLISHInstaller Setting -Ceiling Height SelectionThis function is to adjust FAN Airflow rate according to ceilingheight (only cas
OPTIONAL OPERATIONENGLISH29Installer Setting-Group SettingIt is a function for settings in group control, or 2-remote controller control.Function Code
TIPS FOR SAVING ENERGYENGLISH3• Do not cool excessively indoors. This may be harmful for your health and may consume moreelectricity.• Block sunligh
30OPTIONAL OPERATIONENGLISHFunction Code Dry Contactsetting valueSelect Dry contact setting by pressing button. (00 : Automatic, 01 : manual)3Press
OPTIONAL OPERATIONENGLISH31Installer Setting-Celsius / Fahrenheit SwitchingThis function is used for switching the display between Celsius and Fahrenh
32OPTIONAL OPERATIONENGLISHInstaller Setting -Optional Function SettingSetting feature for indoor unit when air cleaning / heater / humidifier / Up/do
OPTIONAL OPERATIONENGLISH33Installer Setting - Remote controller Mode LockThis function is used to limit ‘operation-mode’ selection setting.code Descr
34HOW TO SET E.S.P?ENGLISHHOW TO SET E.S.P?This is the function that decides the strength of the wind for each wind level and because thisfunction is
HOW TO SET E.S.P?ENGLISH35- Please be careful not to change the ESP value for each fan step.- It does not work to setup ESP value for very low/power s
36ENGLISH
4IMPORTANT SAFETY INSTRUCTIONSENGLISHIMPORTANT SAFETY INSTRUCTIONSREAD ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.Always comply with the following pr
5ENGLISHIMPORTANT SAFETY INSTRUCTIONS• Don’t use a power cord, a plug or a loose socket which isdamaged. - Otherwise, it may cause a fire or electrica
ENGLISHIMPORTANT SAFETY INSTRUCTIONS6• Refrigerant tubing shall be protected or enclosed to avoiddamage.• Flexible refrigerant connectors (such as con
IMPORTANT SAFETY INSTRUCTIONSENGLISH7• Do not step on the indoor/outdoor unit and do not put anythingon it. - It may cause an injury through dropping
8IMPORTANT SAFETY INSTRUCTIONSENGLISH• Keep level parallel in installing the product. - Otherwise, it maycause vibration or water leakage.• Any person
ENGLISH92 MODEL DESIGNATION3 TIPS FOR SAVING ENERGY4 IMPORTANT SAFETY INSTRUCTIONS10 INSTALLATION PLACES12 THE INDOOR UNIT INSTALLATION13 Indoor Unit