INSTALLATION MANUAL
AIR
CONDITIONER
www.lg.com
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring standards by
authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.
4-WAY CEILING CASSETTE
Original instruction (R32)
[Representative] LG Electronics Inc. EU Representative :
LG Electronics European Shared Service Center B.V.
Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro,
Seongsan-gu, Changwon-si, Gyeongsangnam-do, KOREA
Copyright © 2016 - 2017 LG Electronics Inc. All Rights Reserved.
ENGLISH
ITALIANO ESPAÑOL
FRANÇAIS DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
Zobrazit stránku 0
1 2 3 4 5 6 ... 36 37

Shrnutí obsahu

Strany 1 - CONDITIONER

P/NO : MFL67855536INSTALLATION MANUALAIRCONDITIONERwww.lg.comPlease read this installation manual completely before installing the product.Installatio

Strany 2 - MODEL DESIGNATION

10ENGLISHINSTALLATION PLACESINSTALLATION PLACES- There should not be any heat source or steam near the unit. - There should not be any obstacles to pr

Strany 3 - TIPS FOR SAVING ENERGY

ENGLISH11INSTALLATION PLACES- The appliance shall be installed, operated and stored in a room with a floor area larger than the mini-mum area.- Use th

Strany 4 - IMPORTANT SAFETY INSTRUCTIONS

12ENGLISHTHE INDOOR UNIT INSTALLATIONLevel gaugeCeilingCeiling boardUnit:mmUnit:mm875(Ceiling opening)787(Hanging bolt)684(Hanging bolt)671875(Ceiling

Strany 5

ENGLISH13THE INDOOR UNIT INSTALLATIONSet screw ofpaper model (4 pieces)Paper modelfor installationCeilingboard150mmCeiling boardCeiling Flat washer fo

Strany 6

14ENGLISHTHE INDOOR UNIT INSTALLATION700 or less1 -1.5mClamp metal(attached) Drain hose(attached)Drain raising pipe300mm or less300mm or less300mm or

Strany 7

ENGLISH15THE INDOOR UNIT INSTALLATIONPrecautions when laying powerwiringUse round pressure terminals for connectionsto the power terminal block.When n

Strany 8

16THE INDOOR UNIT INSTALLATIONENGLISHFlaring WorkMain cause for gas leakage is due to defect offlaring work. Carry out correct flaring work inthe foll

Strany 9 - TABLE OF CONTENTS

THE INDOOR UNIT INSTALLATIONENGLISH171 Compare the flared work with the figureby.2 If a flared section is defective, cut it offand do flaring work aga

Strany 10 - INSTALLATION PLACES

18THE INDOOR UNIT INSTALLATIONENGLISH2 Set the tubing cutting line upward. Wrap the area which accommodates therear piping housing section with vinyl

Strany 11 - Minimum floor area

REMOTE CONTROLLER INSTALLATIONENGLISH19Please fix tightly using provided screw after placing remote controller setupboard on the place where you like t

Strany 12 - THE INDOOR UNIT INSTALLATION

ENGLISHMODEL DESIGNATION2MODEL DESIGNATION- Product Name : Air conditioner- Model Name :- Additional Information : serial number isrefer to the barcod

Strany 13 - Indoor Unit Drain Piping

20ENGLISHREMOTE CONTROLLER INSTALLATIONPlease fix remote controller upper partinto the setup board attached to the sur-face of the wall, as the picture

Strany 14 - Wiring Connection

ENGLISH21REMOTE CONTROLLER INSTALLATIONWired remote controller installationSince the room temperature sensor is in the remote controller, the remote c

Strany 15 - Precautions when laying power

22ENGLISHINSTALLATION OF DECORATIVE PANEL(ACCESSORY)INSTALLATION OF DECORATIVE PANEL(ACCESSORY)The decorative panel has its installationdirection.Befo

Strany 16 - Flaring Work

ENGLISH23INSTALLATION OF DECORATIVE PANEL(ACCESSORY)5 Fit the corner covers.ScrewInstalling the grill link on the panel bodyInserting the edge into th

Strany 17 - Vinyl tape(narrow)

24ENGLISHAir conditionerunitDecorative panelFit the insulator (this part) and be careful for cool air leakageGood exampleCeilingboardCeilingboardDecor

Strany 18

OPTIONAL OPERATIONENGLISH25Installer Setting -Test Run ModeAfter installing the product, you must run a Test Run mode. For details related to this ope

Strany 19 - <Wire guide grooves>

26OPTIONAL OPERATIONENGLISHInstaller Setting - Setting Address of Central ControlIt's the function to use for connecting central control.Please r

Strany 20 - <Separating order>

OPTIONAL OPERATIONENGLISH27Installer Setting -ThermistorFunction Code Thermistor settingSet Thermistor value by pressing button. (01: Remote Controlle

Strany 21 - Sun ray contact area

28OPTIONAL OPERATIONENGLISHInstaller Setting -Ceiling Height SelectionThis function is to adjust FAN Airflow rate according to ceilingheight (only cas

Strany 22

OPTIONAL OPERATIONENGLISH29Installer Setting-Group SettingIt is a function for settings in group control, or 2-remote controller control.Function Code

Strany 23 - 5 Fit the corner covers

TIPS FOR SAVING ENERGYENGLISH3• Do not cool excessively indoors. This may be harmful for your health and may consume moreelectricity.• Block sunligh

Strany 24 - TEST RUNNING

30OPTIONAL OPERATIONENGLISHFunction Code Dry Contactsetting valueSelect Dry contact setting by pressing button. (00 : Automatic, 01 : manual)3Press

Strany 25 - OPTIONAL OPERATION

OPTIONAL OPERATIONENGLISH31Installer Setting-Celsius / Fahrenheit SwitchingThis function is used for switching the display between Celsius and Fahrenh

Strany 26 - Indoor No

32OPTIONAL OPERATIONENGLISHInstaller Setting -Optional Function SettingSetting feature for indoor unit when air cleaning / heater / humidifier / Up/do

Strany 27 - Installer Setting -Thermistor

OPTIONAL OPERATIONENGLISH33Installer Setting - Remote controller Mode LockThis function is used to limit ‘operation-mode’ selection setting.code Descr

Strany 28

34HOW TO SET E.S.P?ENGLISHHOW TO SET E.S.P?This is the function that decides the strength of the wind for each wind level and because thisfunction is

Strany 29

HOW TO SET E.S.P?ENGLISH35- Please be careful not to change the ESP value for each fan step.- It does not work to setup ESP value for very low/power s

Strany 30

36ENGLISH

Strany 32

4IMPORTANT SAFETY INSTRUCTIONSENGLISHIMPORTANT SAFETY INSTRUCTIONSREAD ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.Always comply with the following pr

Strany 33

5ENGLISHIMPORTANT SAFETY INSTRUCTIONS• Don’t use a power cord, a plug or a loose socket which isdamaged. - Otherwise, it may cause a fire or electrica

Strany 34 - HOW TO SET E.S.P?

ENGLISHIMPORTANT SAFETY INSTRUCTIONS6• Refrigerant tubing shall be protected or enclosed to avoiddamage.• Flexible refrigerant connectors (such as con

Strany 35

IMPORTANT SAFETY INSTRUCTIONSENGLISH7• Do not step on the indoor/outdoor unit and do not put anythingon it. - It may cause an injury through dropping

Strany 36

8IMPORTANT SAFETY INSTRUCTIONSENGLISH• Keep level parallel in installing the product. - Otherwise, it maycause vibration or water leakage.• Any person

Strany 37

ENGLISH92 MODEL DESIGNATION3 TIPS FOR SAVING ENERGY4 IMPORTANT SAFETY INSTRUCTIONS10 INSTALLATION PLACES12 THE INDOOR UNIT INSTALLATION13 Indoor Unit