P/NO : MFL67855504
INSTALLATION MANUAL
AIR CONDITIONER
• Please read this installation manual completely before installing the product.
• Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it
thoroughly.
TYPE : 4-WAY CEILING CASSETTE
www.lg.com
ENGLISH
ITALIANO
ESPAÑOL
FRANÇAIS DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
PORTUGUESE
MAGYAR
БЪЛГАРСKN
SRPSKI
HRVATSKI
SVENDKA
NORSK
SUOMI DANSK
Zobrazit stránku 0
1 2 3 4 5 6 ... 26 27

Shrnutí obsahu

Strany 1 - AIR CONDITIONER

P/NO : MFL67855504INSTALLATION MANUALAIR CONDITIONER • Please read this installation manual completely before installing the product.• Installation wo

Strany 2 - CONTENTS

Remote Controller Installation10 Air ConditionerRemote Controller Installation12323<Wire guide grooves>1. Please fix tightly using provided scre

Strany 3 - Safety Precautions

Installation Manual 11Remote Controller Installation ENGLISHWallSideWallSideWallSideWallSide<Connecting order><Separating order>3. Plea

Strany 4 - 4 Air Conditioner

12 Air ConditionerRemote Controller Installation Wired remote controller installationOperation unitZONE1234HumidifyJETAUTOAUTO SWINGOPERATIONFAN SPE

Strany 5 - Installation Manual 5

Installation Manual 13ENGLISHInstallation to Decorative Panel(Accessory)Installation to Decorative Panel(Accessory)The decorative panel has its insta

Strany 6 - The indoor unit installation

14 Air ConditionerInstallation to Decorative Panel(Accessory)5. Fit the corner covers.6. Open two screws of control panel cover.7. Connect one display

Strany 7 - Tighten the nut and

Installation Manual 15ENGLISHTest running1. PRECAUTIONS IN TEST RUNNING• The initial power supply must provide at least 90% of the rated voltage.Othe

Strany 8 - Indoor Unit Drain Piping

16 Air ConditionerTest running CAUTION: After the confirmation of the above conditions, prepare the wiringas follows:1) Never fail to have an indivi

Strany 9 - Wiring Connection

Installation Manual 17ENGLISHOptional OperationInstaller Setting -Test Run ModeOptional OperationFunction Code SetPress button to start.3Duri

Strany 10 - <Wire guide grooves>

18 Air ConditionerInstaller Setting - Setting Address of Central ControlOptional Operation It's the function to use for connecting central cont

Strany 11 - Installation Manual 11

Installation Manual 19ENGLISHInstaller Setting -ThermistorOptional OperationFunction Code Thermistor settingSet Thermistor value by pressing button.

Strany 12 - Sun ray contact area

2 Air ConditionerSingle A Air Conditioner Installation ManualCONTENTSSafety Precautions ...

Strany 13 - Hook clip

20 Air ConditionerOptional Operation Installer Setting -Ceiling Height SelectionThis function is to adjust FAN Airflow rate according to ceilingheig

Strany 14 - Flexible drain hose

Installation Manual 21ENGLISHInstaller Setting-Group SettingIt is a function for settings in group control, or 2-remote controller control.Function C

Strany 15 - Test running

22 Air ConditionerOptional Operation Installer Setting-Dry Contact Mode SettingFunction Code Dry Contactsetting valueSelect Dry contact setting by p

Strany 16 - HAND OVER

Installation Manual 23ENGLISHInstaller Setting-Celsius / Fahrenheit SwitchingThis function is used for switching the display between Celsius and Fahr

Strany 17 - Optional Operation

24 Air ConditionerOptional Operation Installer Setting -Optional Function SettingSetting feature for indoor unit when air cleaning / heater / humidi

Strany 18 - 18 Air Conditioner

Installation Manual 25ENGLISHHow to Set E.S.P?How to Set E.S.P?If entering into ESP setup mode by using button, it indicates as the picture

Strany 21 - Installation Manual 21

Safety PrecautionsInstallation Manual 3ENGLISHTo prevent the injury of the user or other people and property damage, the following instructionsmust b

Strany 22 - What is Dry Contact?

4 Air ConditionerSafety PrecautionsDo not install the product at a place that thereis concern of falling down.• Otherwise, it may result in personal i

Strany 23 - (Optimized only for U.S.A)

Installation Manual 5Safety Precautions ENGLISHn InstallationInstall the drain hose to ensure that draincan be securely done.• Otherwise, it may ca

Strany 24 - 24 Air Conditioner

6 Air ConditionerInstallation Places1. Indoor unitCassette type• There should not be any heat source or steamnear the unit. • There should not be any

Strany 25 - How to Set E.S.P?

The indoor unit installation Installation Manual 7ENGLISH• Avoid the following installation location.1. Such places as restaurants and kitchen wher

Strany 26 - 26 Air Conditioner

Heat insulation1. Use the heat insulation material for the refrigerant piping which has an excellent heat-resistance (over 120°C).2. Precautions in hi

Strany 27

Installation Manual 9The indoor unit installationWiring ConnectionENGLISH• Open the control box cover and connectthe Remote controller cord and Indoo