LG 3803 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měření, testování a kontrola LG 3803. LG 3803 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - LG 3803

LG 3803 8VSB/QAM SIGNAL GENERATOR INSTRUCTION MANUAL LEADER ELECTRONICS CORP.

Strany 2 - TABLE OF CONTENTS

1.2.5 Installation Do not use the instrument in the following environments. • High temperature environments Do not place the instrument under direct s

Strany 3

2. SPECIFICATIONS 2.1 Description The LG 3803 8VSB/QAM Signal Generator, conforms to 8VSB (digital terrestrial TV in USA System) and 64QAM/256QAM (CAT

Strany 4 - GENERAL SAFETY SUMMARY

2.3 Specifications 2.3.1 Channel Coding Section (1) Broadcasting system Digital Terrestrial (ATSC A/53B) CATV (ITU-T J.83 annex B) (2) Modulation

Strany 5

(4) ASI, SPI Input Specifications Input Packet Format 188 bytes Applicable Stream MPEG-2 TS (ISO/IEC 13818-1) Input Data Rate 25 Mbps max. (5) FR

Strany 6

2.3.6 External Interface (1) Memory Card Interface Memory Card Compact flash card (CFA TYPE-I) Function Updating firmware, changing internal TS-ROM

Strany 7

3. PANEL DESCRIPTIONS 3.1 Front Panel ○18○14 ○13 ○11○4○3 ○21 ○2 ○6 ○9○8○10○12○5 ○16 ○17 ○15○19 ○20 ○7○1 Figure 3-1 LG 380

Strany 8 - 1. INTRODUCTION

○7 MEMORY CARD slot Only used when the memory card contents are upgraded or updated. ○8 UP MENU key While displaying the setting screen, pressin

Strany 9

○16 RECALL key Recalls the setting conditions in the specified address. ○17 ↑, ↓ key Increments and decrements the specified address. ○18 UNIT

Strany 10

3.2 Rear Panel ○22 ○24 ○33○34○27 ○31○32○26 ○31 ○39 ○23 ○25 ○28 ○29 ○30○35○36○37 ○38Figure 3-2 LG 3803 rear panel ○22 FREQ

Strany 11 - 2. SPECIFICATIONS

○31 Cooling fans (Two places) To prevent instrument damage due to overheating, do not block airflow through the ventilation holes. If the fan stop

Strany 12 - 2.3 Specifications

TABLE OF CONTENTS GENERAL SAFETY SUMMARY ... I 1. INTRODUCT

Strany 13

4. LCD PANEL DESCRIPTION 4.1 Turning Power On and Starting Instrument Connect the accessory power cord between the AC inlet on the rear panel and th

Strany 14

8 BER result display Displays the Bit Error Rate (BER) measurement value and GO/NO-GO results based on the threshold values. 9 Interleave Displays

Strany 15 - 3. PANEL DESCRIPTIONS

<<Alarm display on the top screen>> • The following alarm message is displayed on the top screen. Message is displayed in red. [FAN] In

Strany 16

<Setting screen example "CODING"> ○14 ○15 ○16 ○18 ○17 ○16 ○15 ○14 ○16 ○18 ○17 Figure 4-2

Strany 17

<Setting screen example "LEVEL"> ○19 ○19 ○20 Figure 4-3 Setting screen example (2) 19 Numeric value display column

Strany 18 - 3.2 Rear Panel

4.3 Menu The top screen only displays the current setting status; there is no setting items. When changing the setting status, press the MENU key to d

Strany 19

5. USING MENU 5.1 CODING Pressing the CODING key in the MENU group enters setting screen. Figure 5-1 Coding screen This screen is use

Strany 20 - 4. LCD PANEL DESCRIPTION

5.1.1 Source The TS source can be selected by pressing the Source (F1) key on the Coding (L-1) screen. Notes on selecting TS_source • The receiver i

Strany 21

(1) Selecting PN The random signal (PN23) can be output by setting the Source to PN on the TS Source (L-2) screen. (2) Selecting ROM Pattern The patt

Strany 22

5.2 NOISE Figure 5-4 C/N setting screen • Up (F2) Increments the C/N value by preset step size within the acceptable range. • Step

Strany 23

5.4 LEVEL ... 5-6 5.5 BER...

Strany 24

5.3 CHANNEL Figure 5-5 Channel or Frequency setting screen • Country (F1) Selects the channel tables of USA or KOREA. • Up (F2)

Strany 25 - 4.3 Menu

5.4 LEVEL Figure 5-6 Level setting • Up (F2) Increments the level value by preset step size within the acceptable range. • Step S

Strany 26 - 5. USING MENU

5.5 BER Figure 5-7 BER setting and measurement • BER Setup (F1) Sets the BER measurement conditions. Refer to Section 5.5.1. •

Strany 27

5.5.1 BER SETUP Figure 5-8 BER SETUP screen • Interface (F2) Selects the TS input for BER measurement. Parallel Use the SPI connect

Strany 28

5.6 UTILITY Figure 5-9 Utility screen Software Version Displays the control software version. Provide the serial number indicated o

Strany 29 - 5.2 NOISE

5.6.1 CONFIG Figure 5-10 CONFIG screen • TCP/IP (F1) Sets the IP-Address, Subnet Mask and Default Gateway. (Refer to Section 6.5.2) •

Strany 30 - 5.3 CHANNEL

5.6.2 TCP/IP Figure 5-11 TCP/IP screen • Item Select (F5) Selects the item that inputs the numeric value. The values can be directly e

Strany 31 - 5.4 LEVEL

5.6.3 GPIB ADDRESS Figure 5-12 GPIB ADDRESS screen • GPIB Adr. Up (F2) Increments the GPIB ADDRESS within the acceptable range. • G

Strany 32 - 5.5 BER

5.6.4 PRESET GROUP Figure 5-13 PRESET GROUP screen • CF Access (F1) Save the PRESET DATA to the memory card and load it from the me

Strany 33

5.6.5 CF ACCESS Figure 5-14 CF ACCESS screen Status The operation status of SAVE/LOAD to the memory card is displayed. • Preset to C

Strany 34 - 5.6 UTILITY

GENERAL SAFETY SUMMARY To Avoid Personal Injury It is recommended that only qualified personnel with technical knowledge use this instrument only af

Strany 35

6. PRESET, GROUP 6.1 Preset Up to 100 setting conditions can be stored and recalled by using the front panel key. • Storing Data (1) Set the CODING,

Strany 36

7. REMOTE CONTROL This instrument can be remotely controlled (e.g., increments or decrements preset data) via the REMOTE CONTROL connector. (1) Major

Strany 37

8. GPIB Since this instrument provides the GPIB (IEEE 488) connector as standard, major functions can be remotely controlled via the GPIB interface.

Strany 38

8.3 Interface Message Function Table 8-2 Interface message and ASCII code Upper 4 bits 0 1 2 3 4 5 6 7 Lower 4 bits ASC MSG ASC MSG ASC MSG A

Strany 39 - 5.7 Internal Settings

8.5 Clear, Reset The Clear and Reset modes can be controlled by using the commands. The followings describe the reply for the clear and reset operatio

Strany 40 - 6. PRESET, GROUP

8.7 Multiline Message Command Table 8-3 lists the multiline message command types and a reply to each command. Table 8-3 Reply of multiline message

Strany 41 - 7. REMOTE CONTROL

(3) Program message unit separator Use a semicolon ";" (3Bh in ASCII code) when transfers multiple messages simultaneously. (4) Program dat

Strany 42 - 8. GPIB

Table 8-5 Query code list Header Data Description Reply 1 SY ? Reading modulation mode selected n 2 TS ? Reading signal selected to TS

Strany 43 - 8.4 GPIB Address

8.12 Detail Program Code This section describes the detail program codes listed in Section 8.11. Definition: n, p, q, r, s 0 and natural number i I

Strany 44 - 8.6 REMOTE/LOCAL

For Internal (OP70 installed. Reply only; no setting is required.) p Drive Used 0 HDD 1 DVD For ROM p Pattern Selection 0 Color Bar 1 Ramp 2 Monos

Strany 45

GENERAL SAFETY SUMMARY Review the following safety precautions to avoid operator's injury and loss of life and prevent damage and deterioration t

Strany 46 - 8.11 Program Code List

(3) Setting C/N on/off ..."CO" Function Setting and querying C/N set in Step (4) on/off. Syntax CO_n (Setting,

Strany 47 - Table 8-5 Query code list

(9) Reading BER measurement value ..."BR" Function Reading BER measurement value. Syntax ne (Reply) BR_? (Query) BER value ne: Repli

Strany 48 - 8.12 Detail Program Code

(13) Setting BER measurement interval ..."BI" Function Setting and querying BER measurement interval. Syntax BI_p (Setting, reply) BI_? (

Strany 49

(18) Setting frequency in current steps "DF" Function Setting and querying increment/decrement of frequency in current steps. Syntax DF_n

Strany 50

(23) Selecting reference clock "CK" Function Setting and querying reference clock. Syntax CK_n (Setting, reply) CK_? (Query) n Reference

Strany 51

(30) Setting group "GS" Function Setting and querying group. Syntax GS_n, p, q (Setting, reply) GS_n_? (Query) n Group number 0 to 9 p

Strany 52

9. ETHERNET 9.1 Connection When constructing the network system via the ETHER connector, use a STP cable conforming to 100BASE-TX standards. Use a str

Strany 53

10. MAINTENANCE The LG 3803 is designed to operate stably under normal handling. If you have questions regarding calibration and service, contact you

Strany 54

GENERAL SAFETY SUMMARY WARNING Warning on Installation Environments ● About the Guaranteed Operating Temperature Range Operate the instrument bet

Strany 55

GENERAL SAFETY SUMMARY CAUTION Caution on Input/Output Terminals Input Terminals are rated with a maximum input. Do not supply an input over the

Strany 56 - 9. ETHERNET

1. INTRODUCTION Thank you for purchasing Leader’s measuring instruments. Please read this instruction manual carefully to ensure correct and safe oper

Strany 57 - 10. MAINTENANCE

CAUTION 1.2.2 Maximum Input Voltage There is restriction when applying input signals. Applying excessive voltage to the connector may result instru

Komentáře k této Příručce

Žádné komentáře